Customization: | Available |
---|---|
Warranty: | 10 Years |
Number of Cells: | 1PC |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters
|
SUN2000-5KTL-M1
|
SUN2000-6KTL-M1
|
SUN2000-8KTL-M1
|
SUN2000-10KTL-M1
|
SUN2000-12KTL-M1
|
Efficiency
|
|||||
Maximum efficiency
|
98.5%
|
98.5%
|
98.65%
|
98.65%
|
98.65%
|
The input
|
|||||
Maximum DC input voltage
|
1100V
|
||||
Start voltage
|
200v
|
||||
Maximum input current per MPPT channel
|
11A
|
||||
Full load MPPT voltage range
|
240Vdc~850Vdc
|
285Vdc~850Vdc
|
380Vdc~850Vdc
|
470Vdc~850Vdc
|
550Vdc~850Vdc
|
MPPT voltage range
|
160V~1000V
|
||||
Rated input voltage
|
600V
|
||||
Maximum input number
|
2
|
||||
Number of MPPT
|
2
|
||||
The output
|
|||||
Rated output
|
5,000W
|
6,000W
|
8,000W
|
10,000W
|
12,000W
|
Maximum apparent power
|
5,500VA
|
6,600VA
|
8,800VA
|
11,000VA
|
12,000VA
|
Maximum active power
|
5,000W
|
6,000W
|
8,000W
|
10,000W
|
12,000W
|
Rated output voltage
|
230Vac/400Vac,3W/N+PE
|
||||
Output voltage frequency
|
50HZ/60HZ
|
||||
Maximum output current
|
8.6A
|
10.3A
|
13.6A
|
17A
|
18.5A
|
Maximum total harmonic distortion
|
<3%
|
||||
Protection
|
|||||
Input DC switch
|
support
|
||||
Afci DC arc protection
|
support
|
||||
Anti-islanding protection
|
support
|
||||
Output overcurrent protection
|
support
|
||||
Output reverse connection protection
|
support
|
||||
String fault detection
|
support
|
||||
DC surge protection
|
support
|
||||
AC surge protection
|
support
|
||||
Insulation resistance detection
|
support
|
||||
Residual current monitoring
|
support
|
||||
Grid monitoring
|
support
|