Customization: | Available |
---|---|
Warranty: | 5 Years |
Nature of Source Flow: | Active Inverter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
Solis-1P6K-4G-US
|
Solis-1P7K-4G-US
|
Solis-1P7.6K-4G-US
|
Solis-1P8K-4G-US
|
Input DC
|
||||
Max. power per MPPT(Watts):
|
4000
|
4000
|
4000
|
4000
|
Max. DC input power(Watts):
|
7200
|
8400
|
9100
|
9600
|
Max. DC input voltage(V):
|
600
|
600
|
600
|
600
|
Startup voltage(V):
|
120
|
120
|
120
|
120
|
Full power MPPT voltage range(V):
|
200~500
|
233-500
|
253-500
|
182-520
|
Operating MPPT voltage range(V):
|
100-500
|
100-500
|
100-500
|
90-520
|
Max. usable input current per MPPT(A):
|
10+10+10
|
10+10+10
|
10+10+10
|
10+10+10+10
|
Max. short circuit input current(A):
|
15.6+15.6+15.6
|
15.6+15.6+15.6
|
15.6+15.6+15.6
|
15.6+15.6+15.6+15.6
|
Number of MPPT :
|
3
|
3
|
3
|
4
|
Inputs per MPPT:
|
3
|
3
|
3
|
4
|
Output AC
|
||||
Nominal output power(W):
|
6000
|
7000
|
7600
|
8000
|
Max. apparent output power(VA):
|
6000
|
7000
|
7600
|
8000
|
Max. continuous output power(W):
|
6000
|
7000
|
7600
|
8000
|
Operating phase:
|
Single
|
Single
|
Single
|
Single
|
Output power Factor:
|
>0.99
|
>0.99
|
>0.99
|
>0.99
|
Output Power Factor Range:
|
0.8leading ... 0.8lagging
|
|||
Grid current THD:
|
<3%
|
|||
Operating frequency range(Hz):
|
59.5-60.5
|
|||
Operating voltage range(V):
|
183-228(for 208V rate)/211-264(for 240V rated)
|
|||
Max. output current for 240/208V grid(Amps):
|
25/28.8
|
29.2/33.7
|
31.7/36.5
|
33.3/38.5
|
Max. overcurrent protection device 240/208V(Amps):
|
40/40
|
30/30
|
40/50
|
50/50
|
Efficiency
|
||||
Peak efficiency:
|
97.8%
|
97.8%
|
97.8%
|
98.1%
|
CEC weighted efficiency:
|
97.5
|
97.5
|
97.5
|
97.5
|
MPPT efficiency:
|
>99.5%
|
>99.5%
|
>99.5%
|
>99.5%
|
Protection
|
||||
Temperature protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
DC reverse-polarity protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
AC short circuit protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
AC output overcurrent protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Output overvoltage protection-Varistor:
|
Yes
|
Yes
|
Yes
|
Yes
|
Ground fault monitoring:
|
Yes
|
Yes
|
Yes
|
Yes
|
Grid monitoring:
|
Yes
|
Yes
|
Yes
|
Yes
|
Islanding protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Integrated AFCI(DC are-fault circuit protection):
|
Yes
|
Yes
|
Yes
|
Yes
|
Integrated DC switch:
|
Yes
|
Yes
|
Yes
|
Yes
|
Rapid shutdown:
|
Yes
|
Yes
|
Yes
|
Yes
|
General Data
|
||||
Connections:
|
2 knockout for 1"conduit at bottom, 4 knockout for3/4"conduit at side and back
|
|||
Dimensions(W*H*D):
|
13.5*28.8*9.8in(342*732*249mm)
|
|||
Weight (inverter)/Weight (wiring box):
|
45.6lb (20.7kg)
|
|||
Topology:
|
Transformerless
|
|||
Internal consumption:
|
:<1W(Night)
|
|||
Ambient operating temperature range:
|
--25°C~60°C/-13°F-140°F
|
|||
Enclosure type:
|
NEMA 4X
|
|||
Noise emission{typical}:
|
<30 dBA
|
|||
Cooling concept:
|
Natural convection
|
|||
Max operating altitude without derating:
|
13120ft (4000m)
|
|||
Designed lifetime:
|
>20years
|
|||
Compliance:
|
UL 1741, UL 1741SA, UL 1998, UL 1699B, IEEE 1547,FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, Rule 21 Phaes I, II&III
|
|||
Features
|
||||
OTA update:
|
Yes
|
|||
Communication protocol:
|
Sunspec Modbus
|
|||
Communication:
|
optional cellular/WIFI
|
|||
Display:
|
LCD,2×20 Z.
|
|||
Warranty:
|
10 Years STD (Extendable to 20 Years)
|
Quantity(Pieces)
|
1 - 50
|
50 - 100
|
101 - 1000
|
>1000
|
Est. Time(days)
|
10
|
15
|
20
|
To be negotiated
|