1 DC to AC power inverter pure sine wave output;
2 High efficiency toroidal transformer lower loss ;
3 Intelligent LCD integration display;
4 AC charge current 0-20A adjustable; battery capacity configuration more flexible;
5 Three types working modes adjustable:AC first, DC first, energy-saving mode;
6 Frequency adaptive function, adapt to different grid environments;
7 Added fault code query function,facilitate user to monitor the operation state in real time;
8 Supports diesel or gasoline generator, adapt any tough electricity situation;
9 RS485 communication port/APP optional.
| Model WD | 80248/96/192 | 10348/96/192 | 12396/192 | 153192 | 203192 | 253240 | 303240 | 403384 | |
| -802 | -103 | -123 | -153 | -203 | -253 | -303 | -403 | ||
| Rated Power | 8KW | 10KW | 12KW | 15KW | 20KW | 25KW | 30KW | 40KW | |
| Peak Power(20ms) | 24KVA | 30KVA | 36KVA | 45KVA | 60KVA | 75KVA | 90KVA | 120KVA | |
| Start Motor | 5HP | 7HP | 7HP | 10HP | 12HP | 15HP | 15HP | 20HP | |
| Battery Voltage | 48/96/192VDC | 48/96V/192VDC | 96/192VDC | 192VDC | 192VDC | 240VDC | 240VDC | 384VDC | |
| Max AC charging current | 0A~40A(Depending on the model,The maximum | 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power) | |||||||
| charging power is 1/4 of the rated power) | |||||||||
| Size(L*W*Hmm) | 540x350x695 | 593x370x820 | 721x400x1002 | ||||||
| Packing Size(L*W*Hmm) | 600*410*810 | 656*420*937 | 775x465x1120 | ||||||
| N.W.(kg) | 66 | 70 | 77 | 110 | 116 | 123 | 167 | 192 | |
| G.W.(kg) | 77 | 81 | 88 | 124 | 130 | 137 | 190 | 215 | |
| Installation Method | Tower | ||||||||
| Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||||
| AC Input Voltage Range | 73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC) (700W~7000W) | ||||||||
| 92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) / 185VAC~255VAC(220VAC) / 195VAC~265VAC(230VAC) / 205VAC~275VAC( 240VAC) (8KW~40KW) | |||||||||
| AC Input Frequency Range | 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz) | ||||||||
| AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||||
| Output | Efficiency(Battery Mode) | ≥85% | |||||||
| Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||||
| Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 | ||||||||
| Output Wave(Battery Mode) | Pure Sine Wave | ||||||||
| Efficiency(AC Mode) | >99% | ||||||||
| Output Voltage(AC Mode) | Follow input | ||||||||
| Output Frequency(AC Mode) | Tracking Automatically | ||||||||
| Output waveform distortion | ≤3%(Linear load) | ||||||||
| (Battery Mode) | |||||||||
| No load loss(Battery Mode) | ≤1% rated power | ||||||||
| No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||||||
| No load loss | ≤10W | ||||||||
| (Energy saving Mode) | |||||||||
| Battery Type | VRLA Battery | Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | |||||||
| (selectable) | Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements | |||||||
| (charging and discharging parameters of different types of batteries can be set through the operation panel) | |||||||||
| Protection | Battery undervoltage alarm | Factory default: 11V(Single battery voltage) | |||||||
| Battery undervoltage protection | Factory default: 10.5V(Single battery voltage) | ||||||||
| Battery overvoltage alarm | Factory default: 15V(Single battery voltage) | ||||||||
| Battery overvoltage protection | Factory default: 17V(Single battery voltage) | ||||||||
| Battery overvoltage recovery voltage | Factory default: 14.5V(Single battery voltage) | ||||||||
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||
| Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||
| Temperature protection | >90°C(Shut down output) | ||||||||
| Alarm | A | Normal working condition, buzzer has no alarm sound | |||||||
| B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||||
| C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||||
| Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||
| Transfer Time | ≤4ms | ||||||||
| Display | LCD | ||||||||
| Thermal method | Cooling fan in intelligent control | ||||||||
| Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||||
| Environment | Operating temperature | -10ºC~40ºC | |||||||
| Storage temperature | -15ºC~60ºC | ||||||||
| Noise | ≤55dB | ||||||||
| Elevation | 2000m(More than derating) | ||||||||
| Humidity | 0%~95% ,No condensation | ||||||||